<iframe src="//www.googletagmanager.com/ns.html?id=GTM-K2VJGK" height="0" width="0" style="display:none;visibility:hidden">
Aug 31, 2021 6:00:00 AM | 10 Min Read

Not Pumping So Hot? Did you consider NPSH?

Posted By
KSB GIW, Inc.
Share

KSB Cavitation

Centrifugal pumps are fairly robust pieces of equipment and generally deliver the intended results when sized and installed properly. But sometimes, if all factors aren’t considered, one might find themselves with a misbehaving pump (i.e., one that vibrates excessively, fails to deliver the anticipated flow, or even suffers catastrophic damage). When these symptoms are present, a good first step to determining why is to perform an NPSH calculation.

In the pump industry we often jest that NPSH stands for “Not Pumping So Hot,” which is really a symptom, not a cause. NPSH of course stands for Net Positive Suction Head. And if you fail to consider it, it may come back to bite you in the form of a pump that cavitates. NPSH is a technical subject but not a hard one. This article will help a new engineer or plant area manager have a successful pump installation.

DSC01811-cropped
Just as “Kleenex” has become synonymous with “facial tissue,” ‘cavitation’ is often the generic excuse given when a pump doesn’t behave as anticipated. But cavitation has a specific meaning and is not the cause of every misbehaving pump. In the case of centrifugal pumps, cavitation happens when the local pressure inside the suction eye of the impeller — or even in the suction piping leading to the pump — drops below the vapor pressure of the fluid being pumped. When this happens, the liquid inside the pump begins to flash to vapor.

Water vapor occupies up to 1500x more volume than the same mass of liquid water. The thousands of tiny vapor bubbles thus formed will displace liquid in the suction line feeding the pump and is a major part of the reason why a cavitating pump may fail to deliver the desired flow rate. One can also expect a cavitating pump to be less efficient, since centrifugal pumps are designed to pump liquid, not gases like water vapor or air (air entrainment is a subject for another day). In extreme cases of cavitation, the internal parts of a pump can suffer damage. This happens when thousands of small vapor bubbles pass through the impeller and are then re-pressurized. As they pass, the vapor bubbles do the opposite of flashing and collapse vigorously back to liquid in a process called implosion.

shutterstock_1252644757
When implosion happens near the metal parts of a pump — particularly the impeller — it’s as if a small, high pressure water cutting jet is being fired at the pump from close range. And indeed, that’s exactly what is happening. These hundreds of thousands of microjets will remove microscopic bits of metal from the interior of the pump. Mild cases of cavitation may only slightly damage the surface of a part. But severe cases might literally turn a part into “Swiss cheese” if left uncorrected. Other types of damage — to bearings and mechanical seals — are also likely.

Now that we understand what cavitation is, here are some ways to prevent it. NPSH comes in two varieties, NPSHA and NPSHR. As long as NPSHA > NPSHR, cavitation will not happen. NPSHR is a characteristic of the pump and is readily available from its manufacturer for a given duty condition. NPSHA is a function of the entire “system” feeding the pump, which will include:

  • The temperature and vapor pressure of the liquid being pumped
  • The absolute pressure on the free surface of the liquid (usually atmospheric pressure but not always)
  • The size and length of the suction piping and all pipe fittings (e.g., elbows, tees, etc.)
  • The height of the liquid in the supply tank above or below the pump’s centerline

The calculation of NPSHA looks like this:

NPSHA = Hps + Hss – Hf – Hvp where

  • Hps =

    The absolute pressure on the surface of the liquid in the tank supplying the pump. In an open-top tank, this is simply atmospheric pressure. But in an enclosed (closed top) tank this could be either higher or lower (vacuum) than atmospheric pressure. (Remember that atmospheric pressure by definition is zero gauge pressure but always a positive number in absolute terms.) NPSHA is always calculated using absolute terms. It also must be given in terms of head of the liquid being pumped. This will require conversion from units of pressure to units of head.

  • Hss =

    The static suction head either above or below the pump centerline. This number is usually positive but is negative in cases where the pump is above the liquid level in the supply tank (e.g., a suction lift condition).

  • Hf =

    The piping entrance and friction losses from the supply tank to the pump’s suction flange. Hf is a positive number that is always subtracted from Hps when evaluating NPSHA.

  • Hvp =

    The vapor pressure, in absolute units, of the liquid at the temperature it is being pumped. This term is subtracted in the equation because cavitation will happen if the absolute pressure inside the impeller eye or suction piping drops below the liquid vapor pressure. To account for that situation, we simply subtract the vapor pressure of the liquid being pumped. As with Hps, this will require conversion from units of pressure to units of head.

Having defined terms, let’s apply it to a specific instance. Consider a pump mounted some distance away from an open-top tank. The liquid level inside the tank is 6ft (1.8m) above the centerline of the pump, which is at 4000ft (1219m) ASL. The liquid being pumped is water at a temperature of 120F (49C). Assume the total friction losses from the tank to the pump at the desired flow rate are 8ft (2.4m). The pump requires 17ft (5.2m) of NPSHR at the desired flow rate. Will it cavitate?

example1-enlargedExample situation:

  • Hps = 12.7psia (87.5kPa) since that is the average atmospheric pressure at 4000ft (1219m) elevation
  • Hss = 6ft (1.8m)
  • Hf = 8ft (2.4m); Note that friction losses are not a constant, but rather a function of flow rate.
  • Hvp = 1.7psia (11.6kPa); Vapor pressure of water at 120F/49C

NPSHA is therefore:

12.7psia + 6ft – 8ft – 1.69psia (imperial units)

87.5kPa + 1.83m – 2.43m – 11.6kPa (metric units)

Well, not quite. The astute reader will note that it’s as difficult to add or subtract pressure and length as it is to add oranges to apples, so we must make sure that all terms have the same units before performing the calculation. NPSH calculations are made using “head,” and head is measured in units of length. It is known that a column of water exerts approximately 1psi of pressure for every 2.31ft of its height. In metric units a 1m column of water exerts 9.81kPa of pressure. So, 12.7psia (87.5kPa) of atmospheric pressure is equivalent to 29.3ft (8.9m) of head of water column. Similarly, 1.7psia (11.6kPa) of vapor pressure exerts a pressure equivalent to 3.9ft (1.2m) of water column. Substituting, we now have:

NPSHA = 29.3ft + 6ft – 8ft – 3.9ft = 23.4ft (imperial)

NPSHA = 8.9m + 1.8m – 2.4m – 1.2m = 7.1m (metric)

And since 23.4ft (7.1m) > 17ft (5.2m), NPSHA > NPSHR is satisfied, and the pump will not cavitate.

For the sake of simplicity, the example above was calculated using the vapor pressure of water at 120F (49C) and assumed a water specific gravity (SG) of 1.0. In actuality, water’s density varies with both temperature and pressure. For cases where the liquid SG is something other than 1.0, the SG of the liquid is required to make the conversion from pressure to head of liquid, in the following manner:

As above, assume local atmospheric pressure at 4000 ft (1219m) ASL is 12.7psia or 87.5kPa

This time, assume SG of the liquid being pumped is 1.1 (perhaps a light slurry of limestone)

Hps is then

calculation

Hvp should be converted in a similar manner so that it has units of head of the liquid being pumped.

Notice that NPSH is just an energy calculation, (e.g., Bernoulli’s equation). Since a centrifugal pump can’t add energy to a liquid until that liquid is inside the impeller, NPSHA represents all the energy available to feed the pump. NPSHR is essentially a measure of energy loss — measured as pressure drop — as the liquid enters the pump on its way to the impeller, where the pump can begin to add energy — in the form of pressure — back into the liquid. As long as NPSHA > NPSHR, cavitation will not pay an unwelcome visit to your pump installation.

DSC01838

impellerAre you having slurry pump or system problems? GIW is always here to help! Get in touch with us. Contact KSB GIW, Inc..

View all Blogs    Topics: Tech Tips, Mining, GIW, Oil Sands, Slurry Pumps

Related Posts

Mining, GIW, Oil Sands

Cavitation and NPSH

What is Cavitation?

Cavitation occurs when the absolute pressure at the eye of the impeller falls...

Read More
Mining, GIW, Pump Basics

Pump Behaving Badly? It Could Be Air Entrainment

Centrifugal pumps are fairly robust pieces of equipment and generally deliver the intended results...

Read More
Tech Tips, Mining, GIW, Pump Basics, Slurry Pumps

5 Slurry Pump Hacks You Need to Know

It seems like a hack exists for everything these days. From a quicker way to wash your car to...

Read More